Warner-electric POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
Warner Electric • 800-825-9050 819-0452
Torque vs. Current Curve (Typical)
Type: PRB-10H
(kgfm) (lb. ft.)
16
8
4
0
0.6 0.8
1.0
1.6
43.4
57.9
72.3
86.8
101
116
Rated Current 1.33 Amp
Rated Torque 10 Kgfm (72 lb. ft.)
Torque
Current (Amp.)
28.9
14.5
12
1.2
1.4
2
6
10
14
0.4
0.2
Torque vs. Current Curve (Typical)
Type: PRB-20H
(kgfm) (lb. ft.)
30
20
15
0
0.2 0.4
0.6
1.6
36.2
72.3
108
144
181
217
Rated Current 1.58 Amp
Rated Torque 20 Kgfm (144 lb. ft.)
Torque
Current (Amp.)
25
0.8
1.0
10
5
1.2
1.4
Torque (kgfm) = 0.1383 X Torque (lb.ft.)